404 research outputs found

    Quantum dynamics of a qubit coupled with structured bath

    Full text link
    The dynamics of an unbiased spin-boson model with Lorentzian spectral density is investigated theoretically in terms of the perturbation theory based on a unitary transformation. The non-equilibrium correlation function P(t)P(t) and susceptibility χ′′(ω)\chi^{\prime\prime}(\omega) are calculated for both the off-resonance case Δ≲0.5Ω\Delta\lesssim 0.5\Omega and the on-resonance case Δ∼Ω\Delta\sim \Omega. The approach is checked by the Shiba's relation and the sum rule. Besides, the coherent-incoherent transition point αc\alpha_c can be determined, which has not been demonstrated for the structured bath by previous authors up to our knowledge.Comment: 25 pages, 11 figure

    An Innovative Enhanced Wall to Reduce the Energy Demand in Buildings

    Get PDF
    Energy saving in buildings is one of most important issues for European countries. Although in the last years many studies have been carried out in order to reach the zero-consumption house the energy rate due to passive solar heating could be further enhanced. This paper proposes a method for increasing the energy rate absorbed by opaque walls by using a two phase loop thermosyphon connecting the internal and the external façade of a prefabricated house wall. The evaporator zone is embedded into the outside facade and the condenser is indoor placed to heat the domestic environment. The thermosyphon has been preliminary designed and implanted into a wall for a prefabricated house in Italy. An original dynamic thermal model of the building equipped with the thermosyphon wall allowed the evolution of the indoor temperature over time and the energy saving rates. The transient behaviour of the building has been simulated during the winter period by using the EnergyPlusTM software. The annual saving on the heating energy is higher than 50% in the case of a low consumption building

    An Innovative Enhanced Wall to Reduce the Energy Demand in Buildings

    Get PDF
    Energy saving in buildings is one of most important issues for European countries. The 40% of the total European energy consumption is due to building Heating and conditioning. Although in the last years many studies have been carried out in order to reach the zero-consumption house by means of passive solar heating, ventilation or thermal insulation, the energy rate due to passive solar heating could be further enhanced. This paper proposes a method for increasing the energy rate absorbed by opaque walls by using a two phase loop thermosyphon connecting the internal and the external façade of a prefabricated house wall. The evaporator zone is located on the outside face and it is irradiated by the sunlight while the condenser zone is placed on the internal face and releases heat to the domestic environment. The temperature differences between the internal and external wall facades are lower than 30 K and the heat fluxes at the evaporator change during the day from 2 up to 7 x 104 W/m2 K. The thermosyphon has been preliminary designed and implanted into a wall for a prefabricated house in Italy. A thermal model of building equipped with the thermosiphon wall has been used in order to evaluate the impact in terms of energy saving and thermal comfort in a real prefabricated low consumption house. The transient behaviour of the building has been simulated day by day during the winter period by using the EnergyPlusTM software. This solution enhances the thermal comfort of the building by keeping the indoor temperature close to the thermal comfort standard for most of the day. The annual saving on the heating energy is higher than 50% in the case of a low consumption buildin

    Loss and revival of phase coherence in a Bose-Einstein condensate moving through an optical lattice

    Full text link
    We investigate the phase coherence of a trapped Bose-Einstein condensate that undergoes a dynamical superfluid-insulator transition in the presence of a one-dimensional optical lattice. We study the evolution of the condensate after a sudden displacement of the harmonic trapping potential by solving the Gross-Pitaevskii equation, and comparing the results with the prediction of two effective 1D models. We show that, owing to the 3D nature of the system, the breakdown of the superfluid current above a critical displacement is not associated to a sharp transition, but there exists a range of displacements for which the condensate can recover a certain degree of coherence. We also discuss the implications on the interference pattern after the ballistic expansion as measured in recent experiments at LENS.Comment: 7 pages, 9 figure

    Dissipative dynamics of a biased qubit coupled to a harmonic oscillator: Analytical results beyond the rotating wave approximation

    Get PDF
    We study the dissipative dynamics of a biased two-level system (TLS) coupled to a harmonic oscillator (HO), the latter interacting with an Ohmic environment. Using Van-Vleck perturbation theory and going to second order in the coupling between TLS and HO, we show how the Hamiltonian of the TLS-HO system can be diagonalized analytically. Our model represents an improvement to the usually used Jaynes-Cummings Hamiltonian as an initial rotating wave approximation is avoided. By assuming a weak coupling to the thermal bath, analytical expressions for the time evolution of the populations of the TLS are found: the population is characterized by a multiplicity of damped oscillations together with a complex relaxation dynamics towards thermal equilibrium. The long time evolution is characterized by a single relaxation rate, which is largest at resonance and whose expression can be given in closed analytic form.Comment: 39 pages, 17 figures; published versio

    Pore size regulates operating stomatal conductance, while stomatal densities drive the partitioning of conductance between leaf sides

    Get PDF
    Leaf gas exchange is influenced by stomatal size, density, distribution between the leaf adaxial and abaxial sides, as well as by pore dimensions. This study aims to quantify which of these traits mainly underlie genetic differences in operating stomatal conductance (gs) and addresses possible links between anatomical traits and regulation of pore width. Stomatal responsiveness to desiccation, gs-related anatomical traits of each leaf side and estimated gs (based on these traits) were determined for 54 introgression lines (ILs) generated by introgressing segments of Solanum pennelli into the S. lycopersicum ‘M82’. A quantitative trait locus (QTL) analysis for stomatal traits was also performed. A wide genetic variation in stomatal responsiveness to desiccation was observed, a large part of which was explained by stomatal length. Operating gs ranged over a factor of five between ILs. The pore area per stomatal area varied 8-fold among ILs (2–16 %), and was the main determinant of differences in operating gs between ILs. Operating gs was primarily positioned on the abaxial surface (60–83 %), due to higher abaxial stomatal density and, secondarily, to larger abaxial pore area. An analysis revealed 64 QTLs for stomatal traits in the ILs, most of which were in the direction of S. pennellii. The data indicate that operating and maximum gs of non-stressed leaves maintained under stable conditions deviate considerably (by 45–91 %), because stomatal size inadequately reflects operating pore area (R2 = 0·46). Furthermore, it was found that variation between ILs in both stomatal sensitivity to desiccation and operating gs is associated with features of individual stoma. In contrast, genotypic variation in gs partitioning depends on the distribution of stomata between the leaf adaxial and abaxial epidermis
    • …
    corecore